XTi 1002 |
XTi 2002 |
XTi 4002 |
2Ω Stereo (per ch.) |
700W |
1000W |
1600W |
4Ω Stereo (per ch.) |
500W |
800W |
1200W |
8Ω Stereo (per ch.) |
275W |
475W |
650W |
8Ω Bridge-Mono |
1000W |
1600W |
2400W |
4Ω Bridge-Mono |
1400W |
2000W |
3200W |
XTi
There's no debate – when you choose Crown's XTi 2 Series, you're choosing one of the most powerful and innovative amplifiers on the market today. That's because the all-new XTi 2 Series amps continue to set the standard for unmatched performance and value, delivering the goods night after night without breaking a sweat.
Next Generation Features:
- Peakx Plus™ Limiters provide the ultimate in system performance and protection by allowing full control over threshold, attack, and release
- Enhanced Subharmonic Synth section provides user control over frequency, gain and filter type for system-specific tuning
- 3 User-defined fan mode controls – normal, early and fullspeed – for matching fan performance to a specific application
- New system monitoring provides software visibility of AC line voltage and power supply temperature
- Integrated cast-aluminum handles for easy handling and enhanced durability
- Locking power cord clip provides a secure connection between the amplifier and power cord
- Updated HiQnet System Architect™ control software
- Increased number of presets to a total of 50; 49 of which are user definable
Integrated Processing
Input EQ
|
6 parametric filters per channel with adjustable Q, ±15 dB boost/cut. Also adjustable high and low shelving filters. This 8-filter EQ section can be bypassed.
|
Crossover Filters
|
Highpass and Lowpass per channel. Butterworth 6/12/18/24 dB per octave. Linkwitz-Riley 24/48 dB per Octave. Also includes ± 15 dB bandpass gain and polarity control.
|
Output EQ
|
8 parametric filters per channel with adjustable Q, ±15 dB boost/cut. This 8-filter EQ section can be bypassed.
|
Delay
|
For signal alignment of driver; 50 mS of total delay.
|
SubHarmonic Synth
|
Takes the low-frequency content of the input signal and "synthesizes" a new signal that is the same as the input signal but one octave lower. The new synthesized signal is then mixed with the original signal to create the effect. New: Users now have control over frequency, gain, and filter type.
|
Peakx™ Plus Limiter
|
User defeatable limiter that allows users to control Threshold, Attack, and Release times.
|
Presets
|
50 total presets, 49 of which are user-definable.
|
Performance
Sensitivity (for full rated power at 4 ohms)
|
1.4 Vrms |
Frequency Response (at 1 watt, 20 Hz - 20 kHz)
|
+0 dB, –1 dB
|
Signal-to-Noise Ratio (below rated 1kHz power at 8 ohms)
|
XTi1002/2002/4002: 100 dB (A weighted)
XTi6002: 103 dB (A weighted)
|
Total Harmonic Distortion (THD)
|
< 0.5%
|
Damping Factor 20 Hz to 1 kHz
|
> 500
|
Crosstalk (below rated power)
|
20 kHz - 1 kHz: > 70 db
|
Input Impedance (nominal)
|
20k ohms balanced, 10k ohms unbalanced
|
Maximum Input Signal
|
+22 dBu typical
|
AC Line Voltage and Frequency Configurations
|
100 VAC, 120 VAC, 220-240 VAC 50/60 Hz
|
AC Line Current (120 VAC amplifier playing 1/8 power pink noise into 4 ohms per ch)
|
XTi1002: 6.8A; no more than 38W at idle XTi2002: 8.3A; no more
than 38W at idle XTi4002: 10.5A; no more than 38W at idle XTi6002:
15.3A; no more than 180W at idle
|
Operating Temperature
|
0°C to 40°C at 95% relative humidity (non-condensing)
|
Controls
Level
|
Two front-panel rotary level controls, one for each channel
|
Power Switch
|
On/Off switch applies AC power to the amplifier
|
Sel/Prev/Next Buttons
|
Three buttons near the LCD screen that are used to access menu items and front panel lockout
|
LCD Screen
|
Backlit liquid crystal display that shows preset and processing status
|
Indicators
Signal Indicator
|
Green LED, one per channel, illuminates when a very low-level signal is present at input (may be used for troubleshooting cable runs).
|
–10 Indicator
|
Green LED flashes when output signal exceeds -10 dB below clip.
|
–20 Indicator
|
Green LED flashes when output signal level exceeds -20 dB below clip.
|
Ready Indicator
|
Green LED, one per channel, illuminates when the amplifier is ready to produce audio.
|
Clip Indicator
|
Red LED, one per channel, turns on at the threshold of audible distortion
|
Temp Indicator
|
Red LED, one per channel, illuminates under excessive temperature conditions
|
Power Indicator
|
Blue LED illuminates when the amplifier has been turned on and has power
|
Input/Output Connectors
Input Connectors
|
XLR, one per channel
|
Link/Out Connector
|
Loop-thru signal from input connector for linking another amplifier, one per channel.
|
Output Connectors
|
Two Neutrik® Speakon®NL4MP output connectors. Channel-1 Speakon® is wired with Ch. 1 and Ch. 2 outputs for use with optional single 4-conductor cable. Two binding post outputs (in parallel with Speakon® connectors).
|
HiQnet™ USB Connector
|
Type B, connects to HiQnet™ network.
|
Construction
Chassis
|
Steel
|
Front Panel
|
Cast-aluminum
|
Cooling
|
Proportional speed fan with front-to-rear airflow.
|
Dimensions
|
XTi 1002/2002/4002: 19" (W) x 3.5" (H) x 12.25" (D)
|
Net Weight
|
XTi 1002/2002/4002: 18.5 lbs (8.4kg)
|
Shipping Weight
|
XTi 1002/2002/4002: 21.5 lbs (9.8kg)
|